Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Int J Mol Sci ; 23(22)2022 Nov 17.
Article in English | MEDLINE | ID: covidwho-2116210

ABSTRACT

Coronavirus disease-19 (COVID-19) patients are prone to thrombotic complications that may increase morbidity and mortality. These complications are thought to be driven by endothelial activation and tissue damage promoted by the systemic hyperinflammation associated with COVID-19. However, the exact mechanisms contributing to these complications are still unknown. To identify additional mechanisms contributing to the aberrant clotting observed in COVID-19 patients, we analyzed platelets from COVID-19 patients compared to those from controls using mass spectrometry. We identified increased serum amyloid A (SAA) levels, an acute-phase protein, on COVID-19 patients' platelets. In addition, using an in vitro adhesion assay, we showed that healthy platelets adhered more strongly to wells coated with COVID-19 patient serum than to wells coated with control serum. Furthermore, inhibitors of integrin aIIbß3 receptors, a mediator of platelet-SAA binding, reduced platelet adhesion to recombinant SAA and to wells coated with COVID-19 patient serum. Our results suggest that SAA may contribute to the increased platelet adhesion observed in serum from COVID-19 patients. Thus, reducing SAA levels by decreasing inflammation or inhibiting SAA platelet-binding activity might be a valid approach to abrogate COVID-19-associated thrombotic complications.


Subject(s)
COVID-19 , Thrombosis , Humans , Serum Amyloid A Protein/metabolism , COVID-19/complications , Platelet Adhesiveness , Blood Platelets/metabolism , Thrombosis/etiology , Thrombosis/metabolism , Integrins/metabolism , Tissue Adhesions
2.
J Minim Invasive Gynecol ; 27(6): 1256-1257, 2020.
Article in English | MEDLINE | ID: covidwho-1454310

ABSTRACT

STUDY OBJECTIVE: To demonstrate a surgical video wherein a robot-assisted colostomy takedown was performed with anastomosis of the descending colon to the rectum after reduction of ventral hernias and extensive lysis of adhesions. DESIGN: Case report and a step-by-step video demonstration of a robot-assisted colostomy takedown and end-to-side anastomosis. SETTING: Tertiary referral center in New Haven, Connecticut. A 64-year-old female was diagnosed with stage IIIA endometrioid endometrial adenocarcinoma in 2015 when she underwent an optimal cytoreductive surgery. In addition, she required resection of the sigmoid colon and a descending end colostomy with Hartmann's pouch, mainly secondary to extensive diverticulitis. After adjuvant chemoradiation, she remained disease free and desired colostomy reversal. Body mass index at the time was 32 kg/m2. Computed tomography of her abdomen and pelvis did not show any evidence of recurrence but was notable for a large ventral hernia and a parastomal hernia. She then underwent a colonoscopy, which was negative for any pathologic condition, except for some narrowing of the distal rectum above the level of the levator ani. INTERVENTIONS: Enterolysis was extensive and took approximately 2 hours. The splenic flexure of the colon had to be mobilized to provide an adequate proximal limb to the anastomosis site. An anvil was then introduced into the distal descending colon through the colostomy site. A robotic stapler was used to seal the colostomy site and detach it from the anterior abdominal wall. Unfortunately, the 28-mm EEA sizer (Covidien, Dublin, Ireland) perforated through the distal rectum, caudal to the stricture site. A substantial length of the distal rectum had to be sacrificed secondary to the perforation, which mandated further mobilization of the splenic flexure. The rectum was then reapproximated with a 3-0 barbed suture in 2 layers. This provided us with approximately 6- to 8-cm distal rectum. An end-to-side anastomosis of the descending colon to the distal rectum was performed. Anastomotic integrity was confirmed using the bubble test. Because of the lower colorectal anastomosis, a protective diverting loop ileostomy was performed. The patient had an uneventful postoperative course. A hypaque enema performed 3 months after the colostomy takedown showed no evidence of anastomotic leak or stricture. The ileostomy was then reversed without any complications. CONCLUSION: Robot-assisted colostomy takedown and anastomosis of the descending colon to rectum were successfully performed. Although there is a paucity of literature examining this technique within gynecologic surgery, the literature on general surgery has supported laparoscopic Hartmann's reversal and has demonstrated improved rates of postoperative complications and incisional hernia and reduced duration of hospitalization [1]. Minimally invasive technique is a feasible alternative to laparotomy for gynecologic oncology patients who undergo colostomy, as long as the patients are recurrence free.


Subject(s)
Colostomy/adverse effects , Hernia, Ventral/etiology , Hernia, Ventral/surgery , Robotic Surgical Procedures/methods , Tissue Adhesions/etiology , Tissue Adhesions/surgery , Abdominal Wall/surgery , Anastomosis, Surgical/methods , Anastomotic Leak/surgery , Colon, Sigmoid/pathology , Colon, Sigmoid/surgery , Colonic Pouches/adverse effects , Colostomy/methods , Female , Humans , Laparoscopy/methods , Middle Aged , Postoperative Complications/etiology , Postoperative Complications/surgery , Plastic Surgery Procedures/methods , Reoperation/methods , Severity of Illness Index
3.
Ann Vasc Surg ; 70: 286-289, 2021 Jan.
Article in English | MEDLINE | ID: covidwho-805768

ABSTRACT

BACKGROUND: There is increasing evidence supporting coronavirus disease 2019 (COVID-19)-related coagulopathy. In the available literature, only 2 cases of superior mesenteric vein thrombosis have been described. METHODS: We present a peculiar case of high-grade small bowel obstruction in a patient with COVID-19 infection. RESULTS: Exploratory laparotomy revealed a congenital adhesion band with associated focal bowel ischemia contributed by superior mesenteric vein thrombosis and positive lupus anticoagulant. CONCLUSIONS: It is important to consider the rare differential of mesenteric vein thrombosis and its related sequelae of mesenteric ischemia in a patient with COVID-19 who presents with abdominal pain.


Subject(s)
Abdominal Pain/etiology , COVID-19/complications , Digestive System Abnormalities/complications , Mesenteric Ischemia/etiology , Mesenteric Vascular Occlusion/etiology , Mesenteric Veins , Adult , Anticoagulants/therapeutic use , Biomarkers/blood , COVID-19/diagnosis , COVID-19/virology , Digestive System Abnormalities/diagnostic imaging , Digestive System Abnormalities/surgery , Digestive System Surgical Procedures , Host-Pathogen Interactions , Humans , Lupus Coagulation Inhibitor/blood , Male , Mesenteric Ischemia/diagnosis , Mesenteric Ischemia/surgery , Mesenteric Vascular Occlusion/diagnosis , Mesenteric Vascular Occlusion/surgery , Mesenteric Veins/diagnostic imaging , Mesenteric Veins/surgery , SARS-CoV-2/pathogenicity , Tissue Adhesions/congenital , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL